ISSUE:
cannot sign into communicator because your
computer clock is not setup correctly !!!
WHY?
This issue arise when lync server's directory control (DC) clock time is not match up with Lync Client's pc clock time.
SOLUTION:
The easy solution is that to make sure that the Lync DC system time is maximum 5 minute different then Client's PC time.
The smart solution is --
STEP 1. Goto client pc's adjust date and time.
STEP 2. Then on Date and Time window select Internet Time tab.
STEP 3. Now click on Change settings.. a new pop-up named Internet Time Settings will arise.
STEP 4. On Server text field set the Lync DC / active directory IP address and click update now .
STEP 5. Now you will get DC system time and set it by clicking OK.
Subscribe to:
Post Comments (Atom)
How to Generate and use the ssh key on Gerrit, github.io, gitlab, and bitbucket.
Details can be found here -
-
There is none who can replace him.At least the standard which he create in is life time in the running literature it never be replaceable.Th...
-
Server #include <sys/types.h> #include <sys/socket.h> #include <netinet/in.h> #include <arpa/inet.h> #include <...
-
ISSUE: Asterik need SQLITE3 , when it doesn't find this then shows the following warnings - configure: WARNING: *** Asterisk now uses...
No comments:
Post a Comment